A clarification to the cover letter: the reported times are the ones the EC
is configured with, not always the ones it applies. On pwm16 the duty cycle
changed by one per configured time at 300, 700 and 1000 ms, but by one per
200 ms when the time was set to 100 ms. The description of patch 2/2 gives