Remove the DMA setup function. As pointed out by Sergey we set the actual
DMA clock timing in set_dmamode so we don't actually need to do anything
with it at set up time, but just leave the PIO timings loaded.
Signed-off-by: Alan Cox <alan@xxxxxxxxxx>
diff -u --new-file --recursive --exclude-from /usr/src/exclude linux.vanilla-2.6.20-mm2/drivers/ata/pata_sl82c105.c linux-2.6.20-mm2/drivers/ata/pata_sl82c105.c
--- linux.vanilla-2.6.20-mm2/drivers/ata/pata_sl82c105.c 2007-02-20 13:37:58.000000000 +0000
+++ linux-2.6.20-mm2/drivers/ata/pata_sl82c105.c 2007-02-20 13:58:10.000000000 +0000
@@ -7,6 +7,13 @@
* SL82C105/Winbond 553 IDE driver
*
* and in part on the documentation and errata sheet
+ *
+ *
+ * Note: The controller like many controllers has shared timings for
+ * PIO and DMA. We thus flip to the DMA timings in dma_start and flip back
+ * in the dma_stop function. Thus we actually don't need a set_dmamode
+ * method as the PIO method is always called and will set the right PIO
+ * timing parameters.
*/
#include <linux/kernel.h>
@@ -19,7 +26,7 @@
#include <linux/libata.h>
#define DRV_NAME "pata_sl82c105"
-#define DRV_VERSION "0.2.3"
+#define DRV_VERSION "0.2.5"