Re: [lm-sensors] [PATCH] hwmon: Add tempX_emergency to sysfs ABI
From: Henrique de Moraes Holschuh
Date: Thu Aug 26 2010 - 12:10:43 EST
On Thu, 26 Aug 2010, Guenter Roeck wrote:
> Signed-off-by: Guenter Roeck <guenter.roeck@xxxxxxxxxxxx>
> ---
> tempX_emergency will be used by max6696. It can also be used for other chips
> supporting three upper temperature limits.
>
> Documentation/hwmon/sysfs-interface | 6 ++++++
> 1 files changed, 6 insertions(+), 0 deletions(-)
>
> diff --git a/Documentation/hwmon/sysfs-interface b/Documentation/hwmon/sysfs-interface
> index ff45d1f..1ceb2b9 100644
> --- a/Documentation/hwmon/sysfs-interface
> +++ b/Documentation/hwmon/sysfs-interface
> @@ -310,6 +310,12 @@ temp[1-*]_crit_hyst
> from the critical value.
> RW
>
> +temp[1-*]_emergency
> + Temperature emergency value, typically greater than
> + corresponding temp_crit values.
> + Unit: millidegree Celsius
> + RW
> +
If we have two-level alarms: critical, then emergency, it is best to have
that written down than to imply it by "typically greater than corresponding
temp_crit"...
--
"One disk to rule them all, One disk to find them. One disk to bring
them all and in the darkness grind them. In the Land of Redmond
where the shadows lie." -- The Silicon Valley Tarot
Henrique Holschuh
--
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at http://vger.kernel.org/majordomo-info.html