Re: [PATCH v3 4/5] regulator: tps65090: Allow setting the overcurrent wait time

From: Mark Brown
Date: Fri Apr 18 2014 - 11:07:51 EST


On Wed, Apr 16, 2014 at 04:12:28PM -0700, Doug Anderson wrote:
> The tps65090 regulator allows you to specify how long you want it to
> wait before detecting an overcurrent condition. Allow specifying that
> through the device tree (or through platform data).

Applied, thanks.

> +- ti,overcurrent-wait: This is applicable to FET registers, which have a
> + poorly defined "overcurrent wait" field. If this property is present it
> + should be between 0 - 3. If this property isn't present we won't touch the
> + "overcurrent wait" field and we'll leave it to the BIOS/EC to deal with.

What I was driving at by asking if this was the raw register value was
that the binding should make this clearer ideally.

Attachment: signature.asc
Description: Digital signature