On 08/25/2014 07:07 PM, Eduardo Valentin wrote:
> Hello Wei Ni,
>
> On Mon, Aug 25, 2014 at 02:29:47PM +0800, Wei Ni wrote:
>> Add more description for the "polling-delay" property.
>> Set "trips" and "cooling maps" as optional property, because
>> if missing these two sub-nodes, the thermal zone device still
>> work properly.
>>
>> Signed-off-by: Wei Ni <wni@xxxxxxxxxx>
>> ---
>> Documentation/devicetree/bindings/thermal/thermal.txt | 10 ++++++----
>> 1 file changed, 6 insertions(+), 4 deletions(-)
>>
>> diff --git a/Documentation/devicetree/bindings/thermal/thermal.txt b/Documentation/devicetree/bindings/thermal/thermal.txt
>> index f5db6b7..e3d3ed9 100644
>> --- a/Documentation/devicetree/bindings/thermal/thermal.txt
>> +++ b/Documentation/devicetree/bindings/thermal/thermal.txt
>> @@ -136,8 +136,8 @@ containing trip nodes and one sub-node containing all the zone cooling maps.
>>
>> Required properties:
>> - polling-delay: The maximum number of milliseconds to wait between polls
>> - Type: unsigned when checking this thermal zone.
>> - Size: one cell
>> + Type: unsigned when checking this thermal zone. If this value is 0, the
>> + Size: one cell driver will not run polling queue, but just cancel it.
>>
>
> The description above is specific to Linux kernel implementation
> nomenclature. DT description needs to be OS agnostic.
Normally, the user may think a delay of 0 means that software
continually polls this zone, but in here it mean no polling. May be it's
better to add this description.
>
>> - polling-delay-passive: The maximum number of milliseconds to wait
>> Type: unsigned between polls when performing passive cooling.
>> @@ -148,14 +148,16 @@ Required properties:
>> phandles + sensor
>> specifier
>>
>> +Optional property:
>> - trips: A sub-node which is a container of only trip point nodes
>> Type: sub-node required to describe the thermal zone.
>>
>> - cooling-maps: A sub-node which is a container of only cooling device
>> Type: sub-node map nodes, used to describe the relation between trips
>> - and cooling devices.
>> + and cooling devices. If missing the "trips" property,
>> + This sub-node will not be parsed, because no trips can
>> + be bound to cooling devices.
>
> Do you mean if the thermal zone misses the "trips" property? Actually,
> the binding describes both, cooling-maps and trips, as required
> properties. Thus, both needs to be in place to consider the thermal zone
> as a proper described zone.
>
>>
>> -Optional property:
>> - coefficients: An array of integers (one signed cell) containing
>> Type: array coefficients to compose a linear relation between
>> Elem size: one cell the sensors listed in the thermal-sensors property.
>> --
>> 1.8.1.5
>>
--