Re: [PATCH v3 3/4] thermal: add more description for thermal-zones

From: Eduardo Valentin
Date: Tue Aug 26 2014 - 08:09:11 EST


Hi,

On Tue, Aug 26, 2014 at 11:03:21AM +0800, Wei Ni wrote:
> On 08/25/2014 07:07 PM, Eduardo Valentin wrote:
> > Hello Wei Ni,
> >
> > On Mon, Aug 25, 2014 at 02:29:47PM +0800, Wei Ni wrote:
> >> Add more description for the "polling-delay" property.
> >> Set "trips" and "cooling maps" as optional property, because
> >> if missing these two sub-nodes, the thermal zone device still
> >> work properly.
> >>
> >> Signed-off-by: Wei Ni <wni@xxxxxxxxxx>
> >> ---
> >> Documentation/devicetree/bindings/thermal/thermal.txt | 10 ++++++----
> >> 1 file changed, 6 insertions(+), 4 deletions(-)
> >>
> >> diff --git a/Documentation/devicetree/bindings/thermal/thermal.txt b/Documentation/devicetree/bindings/thermal/thermal.txt
> >> index f5db6b7..e3d3ed9 100644
> >> --- a/Documentation/devicetree/bindings/thermal/thermal.txt
> >> +++ b/Documentation/devicetree/bindings/thermal/thermal.txt
> >> @@ -136,8 +136,8 @@ containing trip nodes and one sub-node containing all the zone cooling maps.
> >>
> >> Required properties:
> >> - polling-delay: The maximum number of milliseconds to wait between polls
> >> - Type: unsigned when checking this thermal zone.
> >> - Size: one cell
> >> + Type: unsigned when checking this thermal zone. If this value is 0, the
> >> + Size: one cell driver will not run polling queue, but just cancel it.
> >>
> >
> > The description above is specific to Linux kernel implementation
> > nomenclature. DT description needs to be OS agnostic.
>
> Normally, the user may think a delay of 0 means that software
> continually polls this zone, but in here it mean no polling. May be it's
> better to add this description.
>

Sure, I am fine adding it. Just please do not use Linux specific
nomenclature.

> >
> >> - polling-delay-passive: The maximum number of milliseconds to wait
> >> Type: unsigned between polls when performing passive cooling.
> >> @@ -148,14 +148,16 @@ Required properties:
> >> phandles + sensor
> >> specifier
> >>
> >> +Optional property:
> >> - trips: A sub-node which is a container of only trip point nodes
> >> Type: sub-node required to describe the thermal zone.
> >>
> >> - cooling-maps: A sub-node which is a container of only cooling device
> >> Type: sub-node map nodes, used to describe the relation between trips
> >> - and cooling devices.
> >> + and cooling devices. If missing the "trips" property,
> >> + This sub-node will not be parsed, because no trips can
> >> + be bound to cooling devices.
> >
> > Do you mean if the thermal zone misses the "trips" property? Actually,
> > the binding describes both, cooling-maps and trips, as required
> > properties. Thus, both needs to be in place to consider the thermal zone
> > as a proper described zone.
> >
> >>
> >> -Optional property:
> >> - coefficients: An array of integers (one signed cell) containing
> >> Type: array coefficients to compose a linear relation between
> >> Elem size: one cell the sensors listed in the thermal-sensors property.
> >> --
> >> 1.8.1.5
> >>
>
--
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at http://vger.kernel.org/majordomo-info.html