Re: [PATCH v3 3/4] thermal: add more description for thermal-zones

From: Wei Ni
Date: Tue Aug 26 2014 - 22:32:13 EST


On 08/26/2014 08:08 PM, Eduardo Valentin wrote:
> Hi,
>
> On Tue, Aug 26, 2014 at 11:03:21AM +0800, Wei Ni wrote:
>> On 08/25/2014 07:07 PM, Eduardo Valentin wrote:
>>> Hello Wei Ni,
>>>
>>> On Mon, Aug 25, 2014 at 02:29:47PM +0800, Wei Ni wrote:
>>>> Add more description for the "polling-delay" property.
>>>> Set "trips" and "cooling maps" as optional property, because
>>>> if missing these two sub-nodes, the thermal zone device still
>>>> work properly.
>>>>
>>>> Signed-off-by: Wei Ni <wni@xxxxxxxxxx>
>>>> ---
>>>> Documentation/devicetree/bindings/thermal/thermal.txt | 10 ++++++----
>>>> 1 file changed, 6 insertions(+), 4 deletions(-)
>>>>
>>>> diff --git a/Documentation/devicetree/bindings/thermal/thermal.txt b/Documentation/devicetree/bindings/thermal/thermal.txt
>>>> index f5db6b7..e3d3ed9 100644
>>>> --- a/Documentation/devicetree/bindings/thermal/thermal.txt
>>>> +++ b/Documentation/devicetree/bindings/thermal/thermal.txt
>>>> @@ -136,8 +136,8 @@ containing trip nodes and one sub-node containing all the zone cooling maps.
>>>>
>>>> Required properties:
>>>> - polling-delay: The maximum number of milliseconds to wait between polls
>>>> - Type: unsigned when checking this thermal zone.
>>>> - Size: one cell
>>>> + Type: unsigned when checking this thermal zone. If this value is 0, the
>>>> + Size: one cell driver will not run polling queue, but just cancel it.
>>>>
>>>
>>> The description above is specific to Linux kernel implementation
>>> nomenclature. DT description needs to be OS agnostic.
>>
>> Normally, the user may think a delay of 0 means that software
>> continually polls this zone, but in here it mean no polling. May be it's
>> better to add this description.
>>
>
> Sure, I am fine adding it. Just please do not use Linux specific
> nomenclature.

Yes, you are right, I will just add "Cancel the polling if the delay is 0".

Wei.

>
>>>
>>>> - polling-delay-passive: The maximum number of milliseconds to wait
>>>> Type: unsigned between polls when performing passive cooling.
>>>> @@ -148,14 +148,16 @@ Required properties:
>>>> phandles + sensor
>>>> specifier
>>>>
>>>> +Optional property:
>>>> - trips: A sub-node which is a container of only trip point nodes
>>>> Type: sub-node required to describe the thermal zone.
>>>>
>>>> - cooling-maps: A sub-node which is a container of only cooling device
>>>> Type: sub-node map nodes, used to describe the relation between trips
>>>> - and cooling devices.
>>>> + and cooling devices. If missing the "trips" property,
>>>> + This sub-node will not be parsed, because no trips can
>>>> + be bound to cooling devices.
>>>
>>> Do you mean if the thermal zone misses the "trips" property? Actually,
>>> the binding describes both, cooling-maps and trips, as required
>>> properties. Thus, both needs to be in place to consider the thermal zone
>>> as a proper described zone.
>>>
>>>>
>>>> -Optional property:
>>>> - coefficients: An array of integers (one signed cell) containing
>>>> Type: array coefficients to compose a linear relation between
>>>> Elem size: one cell the sensors listed in the thermal-sensors property.
>>>> --
>>>> 1.8.1.5
>>>>
>>

--
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at http://vger.kernel.org/majordomo-info.html
Please read the FAQ at http://www.tux.org/lkml/