Re: [PATCH 7/9] i8k: Autodetect fan RPM multiplier
From: Greg Kroah-Hartman
Date: Mon Jan 12 2015 - 09:37:47 EST
On Mon, Jan 12, 2015 at 06:19:31AM -0800, Guenter Roeck wrote:
> On 01/12/2015 05:32 AM, Pali Rohár wrote:
> >This patch adds new function i8k_get_fan_nominal_speed() for doing SMM call
> >which will return nominal fan RPM for specified fan speed. It returns nominal
> >RPM value at which fan operate when speed (0, 1, 2, 3) is set. It looks like
> >RPM value is not accurate, but still provides very useful information.
> >
> >New function i8k_get_fan_nominal_speed() is used for determinate if fan
> >multiplier is 1 or 30. If function for maximal fan value success and returned
> >RPM value too high (above 30000) then fan multiplier is set to 1. Otherwise
> >multiplier is not changed and default value 30 is used.
> >
> >Signed-off-by: Pali Rohár <pali.rohar@xxxxxxxxx>
> >Tested-by: Pali Rohár <pali.rohar@xxxxxxxxx>
> >Tested-by: Gabriele Mazzotta <gabriele.mzt@xxxxxxxxx>
>
> Reviewed-by: Guenter Roeck <linux@xxxxxxxxxxxx>
>
> Greg,
>
> with this the entire series is ready to go.
What about patch 9? It doesn't have your ack.
thanks,
greg k-h
--