Re: [RESEND 08/10] regulator: pwm-regulator: Add support for continuous-voltage
From: Mark Brown
Date: Tue Jul 07 2015 - 09:32:25 EST
On Mon, Jul 06, 2015 at 09:58:30AM +0100, Lee Jones wrote:
> + tmp = max_duty_cycle - min_mV * max_duty_cycle / vdiff;
> + pwm_code = tmp + max_duty_cycle * volt_mV / vdiff;
These need some brackets to be clear that they're correct.