Re: [PATCHv2 2/2] drm/panel: simple: Add support for Winstar WF35LTIACD
From: Rob Herring
Date: Fri Mar 24 2017 - 11:59:06 EST
On Mon, Mar 20, 2017 at 02:32:22PM +0100, Richard Genoud wrote:
> This adds support for the Winstar Display Co. WF35LTIACD 3.5" QVGA TFT
> LCD panel, which can be supported by the simple panel driver.
>
> Signed-off-by: Richard Genoud <richard.genoud@xxxxxxxxx>
> ---
>
> Changes since v1:
> Add power-supply property and an example in documentation
>
> .../bindings/display/panel/winstar,wf35ltiacd | 53 ++++++++++++++++++++++
> drivers/gpu/drm/panel/panel-simple.c | 28 ++++++++++++
> 2 files changed, 81 insertions(+)
> create mode 100644 Documentation/devicetree/bindings/display/panel/winstar,wf35ltiacd
>
> diff --git a/Documentation/devicetree/bindings/display/panel/winstar,wf35ltiacd b/Documentation/devicetree/bindings/display/panel/winstar,wf35ltiacd
> new file mode 100644
> index 000000000000..9ff59b868b28
> --- /dev/null
> +++ b/Documentation/devicetree/bindings/display/panel/winstar,wf35ltiacd
> @@ -0,0 +1,53 @@
> +Winstar Display Corporation 3.5" QVGA (320x240) TFT LCD panel
> +
> +Required properties:
> +- compatible: should be "winstar,wf35ltiacd"
> +- power-supply: regulator to provide the VCC supply voltage (3.3 volts)
> +
> +This binding is compatible with the simple-panel binding, which is specified
> +in simple-panel.txt in this directory.
> +
> +Example:
> + backlight: backlight {
> + compatible = "pwm-backlight";
> + pwms = <&hlcdc_pwm 0 50000 PWM_POLARITY_INVERTED>;
> + brightness-levels = <0 31 63 95 127 159 191 223 255>;
> + default-brightness-level = <191>;
> + power-supply = <&bl_reg>;
> + status = "okay";
Drop status from examples.
> + };
> +
> + bl_reg: backlight_regulator {
> + compatible = "regulator-fixed";
> + regulator-name = "backlight-power-supply";
> + regulator-min-microvolt = <5000000>;
> + regulator-max-microvolt = <5000000>;
> + status = "okay";
> + };
> +
> + panel: panel {
> + compatible = "winstar,wf35ltiacd", "simple-panel";
> + backlight = <&backlight>;
> + power-supply = <&panel_reg>;
> + #address-cells = <1>;
> + #size-cells = <0>;
> + status = "okay";
> +
> + port@0 {
> + #address-cells = <1>;
> + #size-cells = <0>;
> +
> + panel_input: endpoint@0 {
> + reg = <0>;
You don't need reg and unit-addresses for these.
With that,
Acked-by: Rob Herring <robh@xxxxxxxxxx>
> + remote-endpoint = <&hlcdc_panel_output>;
> + };
> + };
> + };
> +
> + panel_reg: panel_regulator {
> + compatible = "regulator-fixed";
> + regulator-name = "panel-power-supply";
> + regulator-min-microvolt = <3300000>;
> + regulator-max-microvolt = <3300000>;
> + status = "okay";
> + };