Re: [PATCH] stmmac: Add support for SIMATIC IOT2000 platform

From: Jan Kiszka
Date: Tue Apr 25 2017 - 08:15:22 EST


On 2017-04-25 13:42, Andy Shevchenko wrote:
> On Tue, Apr 25, 2017 at 1:09 PM, Jan Kiszka <jan.kiszka@xxxxxxxxxxx> wrote:
>> On 2017-04-25 12:07, Jan Kiszka wrote:
>>> On 2017-04-25 11:46, Andy Shevchenko wrote:
>>>> On Tue, Apr 25, 2017 at 12:00 PM, Jan Kiszka <jan.kiszka@xxxxxxxxxxx> wrote:
>>>>> On 2017-04-25 09:30, Andy Shevchenko wrote:
>>>>>> On Tue, Apr 25, 2017 at 8:44 AM, Jan Kiszka <jan.kiszka@xxxxxxxxxxx> wrote:
>>>>>>> On 2017-04-24 23:27, Andy Shevchenko wrote:
>>>>>>>> On Mon, Apr 24, 2017 at 10:27 PM, Jan Kiszka <jan.kiszka@xxxxxxxxxxx> wrote:
>
>>>> {
>>>> .name = "SIMATIC IOT2000",
>>>> .func = 6,
>>>> .phy_addr = 1,
>>>> },
>>>> {
>>>> .name = "SIMATIC IOT2000",
>>>> .func = 7,
>>>> .phy_addr = 1,
>>>> },
>>>>
>>>> That's all what you need.
>>>
>>> Nope. Again: the asset tag is the way to tell both apart AND to ensure
>>> that we do not match on future devices.
>
>> To be more verbose: your version (which is our old one) would even
>> enable the second, not connected port on the IOT2020. Incorrectly.
>
> So, name has 2000 for 2020 device? It's clear bug in DMI table you have. :-(
>
> What else do you have in DMI which can be used to distinguish those devices?

Andy, there are devices out there in the field, if we as engineers like
it or not, that are all called "IOT2000" although they are sightly
different inside. This patch accounts for that. And it does that even
without adding "platform_data" hacks like in other patches of mine. ;)

Jan

--
Siemens AG, Corporate Technology, CT RDA ITP SES-DE
Corporate Competence Center Embedded Linux