[PATCH] clk: sunxi-ng: h6: fix PWM gate/reset offset

From: Icenowy Zheng
Date: Fri Aug 10 2018 - 11:17:09 EST


From: Rongyi Chen <chenyi@xxxxxxxxxxx>

Currently the register offset of the PWM bus gate in Allwinner H6 clock
driver is wrong.

Fix this issue.

Fixes: 542353ea ("clk: sunxi-ng: add support for the Allwinner H6 CCU")
Signed-off-by: Rongyi Chen <chenyi@xxxxxxxxxxx>
[Icenowy: refactor commit message]
Signed-off-by: Icenowy Zheng <icenowy@xxxxxxx>
---
drivers/clk/sunxi-ng/ccu-sun50i-h6.c | 2 +-
1 file changed, 1 insertion(+), 1 deletion(-)

diff --git a/drivers/clk/sunxi-ng/ccu-sun50i-h6.c b/drivers/clk/sunxi-ng/ccu-sun50i-h6.c
index bdbfe78fe133..8eea58f9298c 100644
--- a/drivers/clk/sunxi-ng/ccu-sun50i-h6.c
+++ b/drivers/clk/sunxi-ng/ccu-sun50i-h6.c
@@ -352,7 +352,7 @@ static SUNXI_CCU_GATE(bus_dbg_clk, "bus-dbg", "psi-ahb1-ahb2",
static SUNXI_CCU_GATE(bus_psi_clk, "bus-psi", "psi-ahb1-ahb2",
0x79c, BIT(0), 0);

-static SUNXI_CCU_GATE(bus_pwm_clk, "bus-pwm", "apb1", 0x79c, BIT(0), 0);
+static SUNXI_CCU_GATE(bus_pwm_clk, "bus-pwm", "apb1", 0x7ac, BIT(0), 0);

static SUNXI_CCU_GATE(bus_iommu_clk, "bus-iommu", "apb1", 0x7bc, BIT(0), 0);

--
2.18.0