[PATCH 3.16 016/366] staging:iio:ade7854: Fix the wrong number of bits to read

From: Ben Hutchings
Date: Sun Nov 11 2018 - 15:42:19 EST


3.16.61-rc1 review patch. If anyone has any objections, please let me know.

------------------

From: John Syne <rodrigosiqueiramelo@xxxxxxxxx>

commit 6cef2ab01636b6021044f349df466a97c408ec27 upstream.

Fixes: correctly handle the data size in the read operation for I2C

The function ade7854_i2c_read_reg_32() have to invoke the
i2c_master_recv() for read 32 bits values, however, the counter is set
to 3 which means 24 bits. This patch fixes the wrong size of 24 bits, to
32 bits.

Signed-off-by: John Syne <john3909@xxxxxxxxx>
Signed-off-by: Rodrigo Siqueira <rodrigosiqueiramelo@xxxxxxxxx>
Fixes: 8d97a5877 ("staging: iio: meter: new driver for ADE7754 devices")
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@xxxxxxxxxx>
Signed-off-by: Ben Hutchings <ben@xxxxxxxxxxxxxxx>
---
drivers/staging/iio/meter/ade7854-i2c.c | 2 +-
1 file changed, 1 insertion(+), 1 deletion(-)

--- a/drivers/staging/iio/meter/ade7854-i2c.c
+++ b/drivers/staging/iio/meter/ade7854-i2c.c
@@ -191,7 +191,7 @@ static int ade7854_i2c_read_reg_32(struc
if (ret < 0)
goto out;

- ret = i2c_master_recv(st->i2c, st->rx, 3);
+ ret = i2c_master_recv(st->i2c, st->rx, 4);
if (ret < 0)
goto out;