[PATCH V5 0/2] Re-initialize DLL when MCLK is gated dynamically

From: Veerabhadrarao Badiganti
Date: Mon Nov 12 2018 - 01:52:47 EST


On few SDHCI-MSM controllers, the host controller's clock tuning
circuit may go out of sync if controller clocks are gated which
eventually, result in data CRC and command CRC/timeout errors.
To fix this issue, the DLL needs to be re-initialized and restored with
its old settings once clocks are ungated. SDHC cotroller on SDM845 SOC
has this limitation.

Changes since V4:
- Exactly same as V3, posted multiple mails for V4.
So to avoid confusion updating it as V5.

Changes since V3:
- Introduced SoC specific dt compatible string for sdhci-msm
controller
- Moved the condition which checks whether tuning is needed or
not, to a common function.

Changes since V2:
- Removed an unused variable.
- Renamed the newly introduced flags to be more meaningful.
- Added new dt compatible string for SDM845 SOC.

Changes since V1:
- Replaced dt flag with a dt compatible string to
indicate SHDCI-MSM controller varients which need this fix.
- Moved the DLL settings restoration logic from request
context to platform driver runtime pm context.

Tested on: sdm845
Veerabhadrarao Badiganti (2):
dt-bindings: mmc: sdhci-msm: Add SoC-specific compatible strings
mmc: sdhci-msm: Re-initialize DLL if MCLK is gated dynamically

.../devicetree/bindings/mmc/sdhci-msm.txt | 21 ++++--
drivers/mmc/host/sdhci-msm.c | 78 +++++++++++++++++++---
2 files changed, 84 insertions(+), 15 deletions(-)

--
Qualcomm India Private Limited, on behalf of Qualcomm Innovation Center, Inc.
Qualcomm Innovation Center, Inc. is a member of Code Aurora Forum, a Linux Foundation Collaborative Project.