Re: [PATCH] arm64: dts: ls1088a: add one more thermal zone node
From: Shawn Guo
Date: Fri Mar 01 2019 - 08:39:10 EST
On Mon, Feb 25, 2019 at 11:00:49AM +0800, Yuantian Tang wrote:
> Ls1088a has 2 thermal sensors. This patch adds the second node
> to dts to enable it.
Can you elaborate on these 2 thermal sensors/zones, ccu and plt?
Shawn
>
> Signed-off-by: Yuantian Tang <andy.tang@xxxxxxx>
> ---
> arch/arm64/boot/dts/freescale/fsl-ls1088a.dtsi | 43 +++++++++++++++++++++--
> 1 files changed, 39 insertions(+), 4 deletions(-)
>
> diff --git a/arch/arm64/boot/dts/freescale/fsl-ls1088a.dtsi b/arch/arm64/boot/dts/freescale/fsl-ls1088a.dtsi
> index 661137f..9f52bc9 100644
> --- a/arch/arm64/boot/dts/freescale/fsl-ls1088a.dtsi
> +++ b/arch/arm64/boot/dts/freescale/fsl-ls1088a.dtsi
> @@ -129,19 +129,19 @@
> };
>
> thermal-zones {
> - cpu_thermal: cpu-thermal {
> + ccu {
> polling-delay-passive = <1000>;
> polling-delay = <5000>;
> thermal-sensors = <&tmu 0>;
>
> trips {
> - cpu_alert: cpu-alert {
> + ccu_alert: ccu-alert {
> temperature = <85000>;
> hysteresis = <2000>;
> type = "passive";
> };
>
> - cpu_crit: cpu-crit {
> + ccu_crit: ccu-crit {
> temperature = <95000>;
> hysteresis = <2000>;
> type = "critical";
> @@ -150,7 +150,42 @@
>
> cooling-maps {
> map0 {
> - trip = <&cpu_alert>;
> + trip = <&ccu_alert>;
> + cooling-device =
> + <&cpu0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
> + <&cpu1 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
> + <&cpu2 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
> + <&cpu3 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
> + <&cpu4 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
> + <&cpu5 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
> + <&cpu6 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
> + <&cpu7 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>;
> + };
> + };
> + };
> +
> + plt {
> + polling-delay-passive = <1000>;
> + polling-delay = <5000>;
> + thermal-sensors = <&tmu 1>;
> +
> + trips {
> + plt_alert: plt-alert {
> + temperature = <85000>;
> + hysteresis = <2000>;
> + type = "passive";
> + };
> +
> + plt_crit: plt-crit {
> + temperature = <95000>;
> + hysteresis = <2000>;
> + type = "critical";
> + };
> + };
> +
> + cooling-maps {
> + map0 {
> + trip = <&plt_alert>;
> cooling-device =
> <&cpu0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
> <&cpu1 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
> --
> 1.7.1
>