[PATCH v3 1/2] iio/chemical/bme680: Report temperature in millidegrees

From: Mike Looijmans
Date: Wed Mar 06 2019 - 02:31:58 EST


The standard unit for temperature is millidegrees Celcius. Adapt the
driver to report in millidegrees instead of degrees.

Signed-off-by: Mike Looijmans <mike.looijmans@xxxxxxxx>
---
v2: Remove unused 'addr7' variable
v3: Split patch into temperature and SPI

drivers/iio/chemical/bme680_core.c | 16 +++++++---------
1 file changed, 7 insertions(+), 9 deletions(-)

diff --git a/drivers/iio/chemical/bme680_core.c b/drivers/iio/chemical/bme680_core.c
index 70c1fe4..fefe32b 100644
--- a/drivers/iio/chemical/bme680_core.c
+++ b/drivers/iio/chemical/bme680_core.c
@@ -583,8 +583,7 @@ static int bme680_gas_config(struct bme680_data *data)
return ret;
}

-static int bme680_read_temp(struct bme680_data *data,
- int *val, int *val2)
+static int bme680_read_temp(struct bme680_data *data, int *val)
{
struct device *dev = regmap_get_device(data->regmap);
int ret;
@@ -617,10 +616,9 @@ static int bme680_read_temp(struct bme680_data *data,
* compensate_press/compensate_humid to get compensated
* pressure/humidity readings.
*/
- if (val && val2) {
- *val = comp_temp;
- *val2 = 100;
- return IIO_VAL_FRACTIONAL;
+ if (val) {
+ *val = comp_temp * 10; /* Centidegrees to millidegrees */
+ return IIO_VAL_INT;
}

return ret;
@@ -635,7 +633,7 @@ static int bme680_read_press(struct bme680_data *data,
s32 adc_press;

/* Read and compensate temperature to get a reading of t_fine */
- ret = bme680_read_temp(data, NULL, NULL);
+ ret = bme680_read_temp(data, NULL);
if (ret < 0)
return ret;

@@ -668,7 +666,7 @@ static int bme680_read_humid(struct bme680_data *data,
u32 comp_humidity;

/* Read and compensate temperature to get a reading of t_fine */
- ret = bme680_read_temp(data, NULL, NULL);
+ ret = bme680_read_temp(data, NULL);
if (ret < 0)
return ret;

@@ -761,7 +759,7 @@ static int bme680_read_raw(struct iio_dev *indio_dev,
case IIO_CHAN_INFO_PROCESSED:
switch (chan->type) {
case IIO_TEMP:
- return bme680_read_temp(data, val, val2);
+ return bme680_read_temp(data, val);
case IIO_PRESSURE:
return bme680_read_press(data, val, val2);
case IIO_HUMIDITYRELATIVE:
--
1.9.1