[PATCH v6 4/4] iio:temperature: Add MAX31856 thermocouple support
From: Patrick Havelange
Date: Thu Mar 07 2019 - 05:34:40 EST
From: Paresh Chaudhary <paresh.chaudhary@xxxxxxxxxxxxxxxxxxx>
This patch adds support for Maxim MAX31856 thermocouple
temperature sensor support.
More information can be found in:
https://www.maximintegrated.com/en/ds/MAX31856.pdf
NOTE: Driver support only Comparator Mode.
Signed-off-by: Paresh Chaudhary <paresh.chaudhary@xxxxxxxxxxxxxxxxxxx>
Signed-off-by: Matt Weber <matthew.weber@xxxxxxxxxxxxxxxxxxx>
Signed-off-by: Patrick Havelange <patrick.havelange@xxxxxxxxxxxxx>
---
Changes
v1 -> v2
[Peter
1. Fixed all space & 'return' related comments
2. Removed 'sysfs_create_group' api because
iio_device_register function is handling sysfs entry
3. Return -EIO if there is any fault
4. Added check for 'read_size' before spi read call
5. Removed license text from the source file
6. Added .o file in alphabetic order
7. Used #defines instead of magic bits
v2 -> v3
[Jonathan
1. Used bool for fault_oc and fault_ovuv
2. Changed 'max31856_read' function and use byte array to
store registers value.
3. Used 'GENMASK' where required
4. Changed logic 'max31856_thermocouple_read' function. Used
array to read registers value.
5. Used 'devm_iio_device_register' and removed 'max31856_remove'.
6. Fixed other cosmetic changes.
7. Added 'sysfs-bus-iio-temperature-max31856' file and updated
'MAINTAINERS' file.
v3 -> v4
[Jonathan
1. Removed unwanted logic
2. Updated code to handle return value of max31856_read call
3. Added devicetree id table
4. Removed one-shot support from driver as this support was not
implemented with correct design.
v4 -> v5
[Patrick
1. Rename thermocouple type to maxim,thermocouple-type for DT entry
2. Don't cache values from the Fault Status Register
3. Simplify a bit max31856_init()
4. Use IIO_NO_MOD in switch case + default error case
5. Use dev_*() instead of pr_*()
6. Fix missing space in comments
7. Removed iio_info.driver_module assignment as no longer present
8. Don't keep read/write buffer into the internal driver struct
9. Updated kernel version, add missing space in documentation
10. Updated (c) year
11. Removed linux/init.h #include
12. More use of BIT() macro
13. Removed iio_chan_spec.address assignment as not used
14. In max31856_thermocouple_read(), same switch case order as
channels definition
15. Refactor show_fault_*() functions
16. Use u8 as register type in max31856_{read,write}()
v5 -> v6
[Patrick
1. Use generic thermocouple-type property
2. Fix doc for fault_ovuv entry
3. Add check for supported thermocouple-types in probe()
---
.../sysfs-bus-iio-temperature-max31856 | 24 ++
drivers/iio/temperature/Kconfig | 10 +
drivers/iio/temperature/Makefile | 1 +
drivers/iio/temperature/max31856.c | 353 ++++++++++++++++++
4 files changed, 388 insertions(+)
create mode 100644 Documentation/ABI/testing/sysfs-bus-iio-temperature-max31856
create mode 100644 drivers/iio/temperature/max31856.c
diff --git a/Documentation/ABI/testing/sysfs-bus-iio-temperature-max31856 b/Documentation/ABI/testing/sysfs-bus-iio-temperature-max31856
new file mode 100644
index 000000000000..3b3509a3ef2f
--- /dev/null
+++ b/Documentation/ABI/testing/sysfs-bus-iio-temperature-max31856
@@ -0,0 +1,24 @@
+What: /sys/bus/iio/devices/iio:deviceX/fault_oc
+KernelVersion: 5.1
+Contact: linux-iio@xxxxxxxxxxxxxxx
+Description:
+ Open-circuit fault. The detection of open-circuit faults,
+ such as those caused by broken thermocouple wires.
+ Reading returns either '1' or '0'.
+ '1' = An open circuit such as broken thermocouple wires
+ has been detected.
+ '0' = No open circuit or broken thermocouple wires are detected
+
+What: /sys/bus/iio/devices/iio:deviceX/fault_ovuv
+KernelVersion: 5.1
+Contact: linux-iio@xxxxxxxxxxxxxxx
+Description:
+ Overvoltage or Undervoltage Input Fault. The internal circuitry
+ is protected from excessive voltages applied to the thermocouple
+ cables by integrated MOSFETs at the T+ and T- inputs, and the
+ BIAS output. These MOSFETs turn off when the input voltage is
+ negative or greater than VDD.
+ Reading returns either '1' or '0'.
+ '1' = The input voltage is negative or greater than VDD.
+ '0' = The input voltage is positive and less than VDD (normal
+ state).
diff --git a/drivers/iio/temperature/Kconfig b/drivers/iio/temperature/Kconfig
index 82e4a62745e2..c66eeb23615b 100644
--- a/drivers/iio/temperature/Kconfig
+++ b/drivers/iio/temperature/Kconfig
@@ -97,4 +97,14 @@ config TSYS02D
This driver can also be built as a module. If so, the module will
be called tsys02d.
+config MAX31856
+ tristate "MAX31856 thermocouple sensor"
+ depends on SPI
+ help
+ If you say yes here you get support for MAX31856
+ thermocouple sensor chip connected via SPI.
+
+ This driver can also be built as a module. If so, the module
+ will be called max31856.
+
endmenu
diff --git a/drivers/iio/temperature/Makefile b/drivers/iio/temperature/Makefile
index 34a31db0bb63..baca4776ca0d 100644
--- a/drivers/iio/temperature/Makefile
+++ b/drivers/iio/temperature/Makefile
@@ -5,6 +5,7 @@
obj-$(CONFIG_HID_SENSOR_TEMP) += hid-sensor-temperature.o
obj-$(CONFIG_MAXIM_THERMOCOUPLE) += maxim_thermocouple.o
+obj-$(CONFIG_MAX31856) += max31856.o
obj-$(CONFIG_MLX90614) += mlx90614.o
obj-$(CONFIG_MLX90632) += mlx90632.o
obj-$(CONFIG_TMP006) += tmp006.o
diff --git a/drivers/iio/temperature/max31856.c b/drivers/iio/temperature/max31856.c
new file mode 100644
index 000000000000..6b67d6b95cf9
--- /dev/null
+++ b/drivers/iio/temperature/max31856.c
@@ -0,0 +1,353 @@
+// SPDX-License-Identifier: GPL-2.0
+/* max31856.c
+ *
+ * Maxim MAX31856 thermocouple sensor driver
+ *
+ * Copyright (C) 2018-2019 Rockwell Collins
+ */
+
+#include <linux/module.h>
+#include <linux/init.h>
+#include <linux/err.h>
+#include <linux/spi/spi.h>
+#include <linux/iio/iio.h>
+#include <linux/iio/sysfs.h>
+#include <dt-bindings/iio/temperature/thermocouple.h>
+/*
+ * The MSB of the register value determines whether the following byte will
+ * be written or read. If it is 0, one or more byte reads will follow.
+ */
+#define MAX31856_RD_WR_BIT BIT(7)
+
+#define MAX31856_CR0_AUTOCONVERT BIT(7)
+#define MAX31856_CR0_1SHOT BIT(6)
+#define MAX31856_CR0_OCFAULT BIT(4)
+#define MAX31856_CR0_OCFAULT_MASK GENMASK(5, 4)
+#define MAX31856_TC_TYPE_MASK GENMASK(3, 0)
+#define MAX31856_FAULT_OVUV BIT(1)
+#define MAX31856_FAULT_OPEN BIT(0)
+
+/* The MAX31856 registers */
+#define MAX31856_CR0_REG 0x00
+#define MAX31856_CR1_REG 0x01
+#define MAX31856_MASK_REG 0x02
+#define MAX31856_CJHF_REG 0x03
+#define MAX31856_CJLF_REG 0x04
+#define MAX31856_LTHFTH_REG 0x05
+#define MAX31856_LTHFTL_REG 0x06
+#define MAX31856_LTLFTH_REG 0x07
+#define MAX31856_LTLFTL_REG 0x08
+#define MAX31856_CJTO_REG 0x09
+#define MAX31856_CJTH_REG 0x0A
+#define MAX31856_CJTL_REG 0x0B
+#define MAX31856_LTCBH_REG 0x0C
+#define MAX31856_LTCBM_REG 0x0D
+#define MAX31856_LTCBL_REG 0x0E
+#define MAX31856_SR_REG 0x0F
+
+static const struct iio_chan_spec max31856_channels[] = {
+ { /* Thermocouple Temperature */
+ .type = IIO_TEMP,
+ .info_mask_separate =
+ BIT(IIO_CHAN_INFO_RAW) | BIT(IIO_CHAN_INFO_SCALE),
+ },
+ { /* Cold Junction Temperature */
+ .type = IIO_TEMP,
+ .channel2 = IIO_MOD_TEMP_AMBIENT,
+ .modified = 1,
+ .info_mask_separate =
+ BIT(IIO_CHAN_INFO_RAW) | BIT(IIO_CHAN_INFO_SCALE),
+ },
+};
+
+struct max31856_data {
+ struct spi_device *spi;
+ u32 thermocouple_type;
+};
+
+static int max31856_read(struct max31856_data *data, u8 reg,
+ u8 val[], unsigned int read_size)
+{
+ return spi_write_then_read(data->spi, ®, 1, val, read_size);
+}
+
+static int max31856_write(struct max31856_data *data, u8 reg,
+ unsigned int val)
+{
+ u8 buf[2];
+
+ buf[0] = reg | (MAX31856_RD_WR_BIT);
+ buf[1] = val;
+
+ return spi_write(data->spi, buf, 2);
+}
+
+static int max31856_init(struct max31856_data *data)
+{
+ int ret;
+ u8 reg_cr0_val, reg_cr1_val;
+
+ /* Start by changing to Off mode before making changes as
+ * some settings are recommended to be set only when the device
+ * is off
+ */
+ ret = max31856_read(data, MAX31856_CR0_REG, ®_cr0_val, 1);
+ if (ret)
+ return ret;
+
+ reg_cr0_val &= ~MAX31856_CR0_AUTOCONVERT;
+ ret = max31856_write(data, MAX31856_CR0_REG, reg_cr0_val);
+ if (ret)
+ return ret;
+
+ /* Set thermocouple type based on dts property */
+ ret = max31856_read(data, MAX31856_CR1_REG, ®_cr1_val, 1);
+ if (ret)
+ return ret;
+
+ reg_cr1_val &= ~MAX31856_TC_TYPE_MASK;
+ reg_cr1_val |= data->thermocouple_type;
+ ret = max31856_write(data, MAX31856_CR1_REG, reg_cr1_val);
+ if (ret)
+ return ret;
+
+ /*
+ * Enable Open circuit fault detection
+ * Read datasheet for more information: Table 4.
+ * Value 01 means : Enabled (Once every 16 conversions)
+ */
+ reg_cr0_val &= ~MAX31856_CR0_OCFAULT_MASK;
+ reg_cr0_val |= MAX31856_CR0_OCFAULT;
+
+ /* Set Auto Conversion Mode */
+ reg_cr0_val &= ~MAX31856_CR0_1SHOT;
+ reg_cr0_val |= MAX31856_CR0_AUTOCONVERT;
+
+ return max31856_write(data, MAX31856_CR0_REG, reg_cr0_val);
+}
+
+static int max31856_thermocouple_read(struct max31856_data *data,
+ struct iio_chan_spec const *chan,
+ int *val)
+{
+ int ret, offset_cjto;
+ u8 reg_val[3];
+
+ switch (chan->channel2) {
+ case IIO_NO_MOD:
+ /*
+ * Multibyte Read
+ * MAX31856_LTCBH_REG, MAX31856_LTCBM_REG, MAX31856_LTCBL_REG
+ */
+ ret = max31856_read(data, MAX31856_LTCBH_REG, reg_val, 3);
+ if (ret)
+ return ret;
+ /* Skip last 5 dead bits of LTCBL */
+ *val = (reg_val[0] << 16 | reg_val[1] << 8 | reg_val[2]) >> 5;
+ /* Check 7th bit of LTCBH reg. value for sign*/
+ if (reg_val[0] & 0x80)
+ *val -= 0x80000;
+ break;
+
+ case IIO_MOD_TEMP_AMBIENT:
+ /*
+ * Multibyte Read
+ * MAX31856_CJTO_REG, MAX31856_CJTH_REG, MAX31856_CJTL_REG
+ */
+ ret = max31856_read(data, MAX31856_CJTO_REG, reg_val, 3);
+ if (ret)
+ return ret;
+ /* Get Cold Junction Temp. offset register value */
+ offset_cjto = reg_val[0];
+ /* Get CJTH and CJTL value and skip last 2 dead bits of CJTL */
+ *val = (reg_val[1] << 8 | reg_val[2]) >> 2;
+ /* As per datasheet add offset into CJTH and CJTL */
+ *val += offset_cjto;
+ /* Check 7th bit of CJTH reg. value for sign */
+ if (reg_val[1] & 0x80)
+ *val -= 0x4000;
+ break;
+
+ default:
+ return -EINVAL;
+ }
+
+ ret = max31856_read(data, MAX31856_SR_REG, reg_val, 1);
+ if (ret)
+ return ret;
+ /* Check for over/under voltage or open circuit fault */
+ if (reg_val[0] & (MAX31856_FAULT_OVUV | MAX31856_FAULT_OPEN))
+ return -EIO;
+
+ return ret;
+}
+
+static int max31856_read_raw(struct iio_dev *indio_dev,
+ struct iio_chan_spec const *chan,
+ int *val, int *val2, long mask)
+{
+ struct max31856_data *data = iio_priv(indio_dev);
+ int ret;
+
+ switch (mask) {
+ case IIO_CHAN_INFO_RAW:
+ ret = max31856_thermocouple_read(data, chan, val);
+ if (ret)
+ return ret;
+ return IIO_VAL_INT;
+ case IIO_CHAN_INFO_SCALE:
+ switch (chan->channel2) {
+ case IIO_MOD_TEMP_AMBIENT:
+ /* Cold junction Temp. Data resolution is 0.015625 */
+ *val = 15;
+ *val2 = 625000; /* 1000 * 0.015625 */
+ ret = IIO_VAL_INT_PLUS_MICRO;
+ break;
+ default:
+ /* Thermocouple Temp. Data resolution is 0.0078125 */
+ *val = 7;
+ *val2 = 812500; /* 1000 * 0.0078125) */
+ return IIO_VAL_INT_PLUS_MICRO;
+ }
+ break;
+ }
+
+ return ret;
+}
+
+static ssize_t show_fault(struct device *dev, u8 faultbit, char *buf)
+{
+ struct iio_dev *indio_dev = dev_to_iio_dev(dev);
+ struct max31856_data *data = iio_priv(indio_dev);
+ u8 reg_val;
+ int ret;
+ bool fault;
+
+ ret = max31856_read(data, MAX31856_SR_REG, ®_val, 1);
+ if (ret)
+ return ret;
+
+ fault = reg_val & faultbit;
+
+ return sprintf(buf, "%d\n", fault);
+}
+
+static ssize_t show_fault_ovuv(struct device *dev,
+ struct device_attribute *attr,
+ char *buf)
+{
+ return show_fault(dev, MAX31856_FAULT_OVUV, buf);
+}
+
+static ssize_t show_fault_oc(struct device *dev,
+ struct device_attribute *attr,
+ char *buf)
+{
+ return show_fault(dev, MAX31856_FAULT_OPEN, buf);
+}
+
+static IIO_DEVICE_ATTR(fault_ovuv, 0444, show_fault_ovuv, NULL, 0);
+static IIO_DEVICE_ATTR(fault_oc, 0444, show_fault_oc, NULL, 0);
+
+static struct attribute *max31856_attributes[] = {
+ &iio_dev_attr_fault_ovuv.dev_attr.attr,
+ &iio_dev_attr_fault_oc.dev_attr.attr,
+ NULL,
+};
+
+static const struct attribute_group max31856_group = {
+ .attrs = max31856_attributes,
+};
+
+static const struct iio_info max31856_info = {
+ .read_raw = max31856_read_raw,
+ .attrs = &max31856_group,
+};
+
+static int max31856_probe(struct spi_device *spi)
+{
+ const struct spi_device_id *id = spi_get_device_id(spi);
+ struct iio_dev *indio_dev;
+ struct max31856_data *data;
+ int ret;
+
+ indio_dev = devm_iio_device_alloc(&spi->dev, sizeof(*data));
+ if (!indio_dev)
+ return -ENOMEM;
+
+ data = iio_priv(indio_dev);
+ data->spi = spi;
+
+ spi_set_drvdata(spi, indio_dev);
+
+ indio_dev->info = &max31856_info;
+ indio_dev->name = id->name;
+ indio_dev->modes = INDIO_DIRECT_MODE;
+ indio_dev->channels = max31856_channels;
+ indio_dev->num_channels = ARRAY_SIZE(max31856_channels);
+
+ ret = of_property_read_u32(spi->dev.of_node, "thermocouple-type",
+ &data->thermocouple_type);
+
+ if (ret) {
+ dev_info(&spi->dev,
+ "Could not read thermocouple type DT property, configuring as a K-Type\n");
+ data->thermocouple_type = THERMOCOUPLE_TYPE_K;
+ }
+
+ /*
+ * no need to translate values as the supported types
+ * have the same value as the #defines
+ */
+ switch (data->thermocouple_type) {
+ case THERMOCOUPLE_TYPE_B:
+ case THERMOCOUPLE_TYPE_E:
+ case THERMOCOUPLE_TYPE_J:
+ case THERMOCOUPLE_TYPE_K:
+ case THERMOCOUPLE_TYPE_N:
+ case THERMOCOUPLE_TYPE_R:
+ case THERMOCOUPLE_TYPE_S:
+ case THERMOCOUPLE_TYPE_T:
+ break;
+ default:
+ dev_err(&spi->dev,
+ "error: thermocouple-type %u not supported by max31856\n"
+ , data->thermocouple_type);
+ return -EINVAL;
+ }
+
+ ret = max31856_init(data);
+ if (ret) {
+ dev_err(&spi->dev, "error: Failed to configure max31856\n");
+ return ret;
+ }
+
+ return devm_iio_device_register(&spi->dev, indio_dev);
+}
+
+static const struct spi_device_id max31856_id[] = {
+ { "max31856", 0 },
+ { }
+};
+MODULE_DEVICE_TABLE(spi, max31856_id);
+
+static const struct of_device_id max31856_of_match[] = {
+ { .compatible = "maxim,max31856" },
+ { }
+};
+MODULE_DEVICE_TABLE(of, max31856_of_match);
+
+static struct spi_driver max31856_driver = {
+ .driver = {
+ .name = "max31856",
+ .of_match_table = max31856_of_match,
+ },
+ .probe = max31856_probe,
+ .id_table = max31856_id,
+};
+module_spi_driver(max31856_driver);
+
+MODULE_AUTHOR("Paresh Chaudhary <paresh.chaudhary@xxxxxxxxxxxxxxxxxxx>");
+MODULE_AUTHOR("Patrick Havelange <patrick.havelange@xxxxxxxxxxxxx>");
+MODULE_DESCRIPTION("Maxim MAX31856 thermocouple sensor driver");
+MODULE_LICENSE("GPL");
--
2.19.1