Re: [PATCHv2 1/5] Documentation: dt: edac: Fix Stratix10 IRQ bindings

From: Thor Thayer
Date: Tue Mar 12 2019 - 15:13:40 EST


Hi Rob,

On 3/12/19 11:00 AM, Rob Herring wrote:
On Wed, Feb 27, 2019 at 11:27:21AM -0600, thor.thayer@xxxxxxxxxxxxxxx wrote:
From: Thor Thayer <thor.thayer@xxxxxxxxxxxxxxx>

Fix Stratix10 ECC bindings to specify only the single
bit error. On Stratix10 double bit errors are handled
as SErrors instead of interrupts.
Indicate the differences between the ARM64 and ARM32
EDAC architecture in the bindings.

Signed-off-by: Thor Thayer <thor.thayer@xxxxxxxxxxxxxxx>
---
v2 No change
---
.../devicetree/bindings/edac/socfpga-eccmgr.txt | 23 +++++++++++++++-------
1 file changed, 16 insertions(+), 7 deletions(-)

diff --git a/Documentation/devicetree/bindings/edac/socfpga-eccmgr.txt b/Documentation/devicetree/bindings/edac/socfpga-eccmgr.txt
index 5626560a6cfd..a0ac50e15912 100644
--- a/Documentation/devicetree/bindings/edac/socfpga-eccmgr.txt
+++ b/Documentation/devicetree/bindings/edac/socfpga-eccmgr.txt
@@ -236,33 +236,42 @@ Stratix10 SoCFPGA ECC Manager
The Stratix10 SoC ECC Manager handles the IRQs for each peripheral
in a shared register similar to the Arria10. However, ECC requires
access to registers that can only be read from Secure Monitor with
-SMC calls. Therefore the device tree is slightly different.
+SMC calls. Therefore the device tree is slightly different. Note that
+only 1 interrupt is sent because the double bit errors are treated as
+SErrors instead of IRQ.
Required Properties:
- compatible : Should be "altr,socfpga-s10-ecc-manager"
-- interrupts : Should be single bit error interrupt, then double bit error
- interrupt.
+- altr,sysgr-syscon : phandle to Stratix10 System Manager Block
+ containing the ECC manager registers.

Seems this was already in use, but why not just make this node a child
of the System Manager Block and remove this phandle?

Yes, this was already in use but I'm trying to fix that oversight with this patch.

The System Manager is a collection of registers used by different peripherals including EMAC and ECC.

I view ECC Manager as a separate entity as is the Ethernet MAC which is why I have it separate. Using the phandle also follows the convention established with the Arria10 ECC Manager.

Thanks for the comments and for reviewing!

Thor

+- interrupts : Should be single bit error interrupt.
- interrupt-controller : boolean indicator that ECC Manager is an interrupt controller
- #interrupt-cells : must be set to 2.
+- #address-cells: must be 1
+- #size-cells: must be 1
+- ranges : standard definition, should translate from local addresses
Subcomponents:
SDRAM ECC
Required Properties:
- compatible : Should be "altr,sdram-edac-s10"
-- interrupts : Should be single bit error interrupt, then double bit error
- interrupt, in this order.
+- interrupts : Should be single bit error interrupt.
Example:
eccmgr {
compatible = "altr,socfpga-s10-ecc-manager";
- interrupts = <0 15 4>, <0 95 4>;
+ altr,sysmgr-syscon = <&sysmgr>;
+ #address-cells = <1>;
+ #size-cells = <1>;
+ interrupts = <0 15 4>;
interrupt-controller;
#interrupt-cells = <2>;
+ ranges;
sdramedac {
compatible = "altr,sdram-edac-s10";
- interrupts = <16 4>, <48 4>;
+ interrupts = <16 IRQ_TYPE_LEVEL_HIGH>;
};
};
--
2.7.4