at 4:52 PM, Paul Menzel <pmenzel@xxxxxxxxxxxxx> wrote:

Dear Kai-Heng,


Thank you for the patch.

On 7/15/19 10:43 AM, Kai-Heng Feng wrote:
After hotplugging an 1Gbps ethernet cable with 1Gbps link partner, the
MII_BMSR may reports 10Mbps, renders the network rather slow.

s/may reports/may report/
s/renders/rendering/

Apparently English isnât my mother tongue ;)


The issue has much lower fail rate after commit 59653e6497d1 ("e1000e:
Make watchdog use delayed work"), which esssentially introduces some

essentially

Ok.


delay before running the watchdog task.

But there's still a chance that the hotplugging event and the queued
watchdog task gets run at the same time, then the original issue can be
observed once again.

So let's use mod_delayed_work() to add a deterministic 1 second delay
before running watchdog task, after an interrupt.

I am not clear about the effects for the user. Could you elaborate
please? Does the link now come up up to one second later?

Yes, the link will be up on a fixed one second later.

The delay varies between 0 to 2 seconds without this patch.


Signed-off-by: Kai-Heng Feng <kai.heng.feng@xxxxxxxxxxxxx>

Any bug URL?

If maintainers think itâs necessary then Iâll file one.

Kai-Heng


---
drivers/net/ethernet/intel/e1000e/netdev.c | 12 ++++++------
1 file changed, 6 insertions(+), 6 deletions(-)


Kind regards,