[PATCH 5/5] leds: lm3692x: Use flags from LM3692X_BRT_CTRL

From: Guido GÃnther
Date: Tue Sep 17 2019 - 22:20:12 EST


Use LM3692X_RAMP_EN instead of LM3692X_PWM_HYSTER_4LSB
since the later is a flag for the PWM register. The
actual register value remains unchanged.

Signed-off-by: Guido GÃnther <agx@xxxxxxxxxxx>
---
drivers/leds/leds-lm3692x.c | 2 +-
1 file changed, 1 insertion(+), 1 deletion(-)

diff --git a/drivers/leds/leds-lm3692x.c b/drivers/leds/leds-lm3692x.c
index d673f706385e..ecac586ca89c 100644
--- a/drivers/leds/leds-lm3692x.c
+++ b/drivers/leds/leds-lm3692x.c
@@ -269,7 +269,7 @@ static int lm3692x_init(struct lm3692x_led *led)
goto out;

ret = regmap_write(led->regmap, LM3692X_BRT_CTRL,
- LM3692X_BL_ADJ_POL | LM3692X_PWM_HYSTER_4LSB);
+ LM3692X_BL_ADJ_POL | LM3692X_RAMP_EN);
if (ret)
goto out;

--
2.23.0.rc1