[PATCH AUTOSEL 4.14 25/89] md: don't call spare_active in md_reap_sync_thread if all member devices can't work
From: Sasha Levin
Date: Sun Sep 22 2019 - 15:12:48 EST
From: Guoqing Jiang <jgq516@xxxxxxxxx>
[ Upstream commit 0d8ed0e9bf9643f27f4816dca61081784dedb38d ]
When add one disk to array, the md_reap_sync_thread is responsible
to activate the spare and set In_sync flag for the new member in
spare_active().
But if raid1 has one member disk A, and disk B is added to the array.
Then we offline A before all the datas are synchronized from A to B,
obviously B doesn't have the latest data as A, but B is still marked
with In_sync flag.
So let's not call spare_active under the condition, otherwise B is
still showed with 'U' state which is not correct.
Signed-off-by: Guoqing Jiang <guoqing.jiang@xxxxxxxxxxxxxxx>
Signed-off-by: Song Liu <songliubraving@xxxxxx>
Signed-off-by: Sasha Levin <sashal@xxxxxxxxxx>
---
drivers/md/md.c | 3 ++-
1 file changed, 2 insertions(+), 1 deletion(-)
diff --git a/drivers/md/md.c b/drivers/md/md.c
index 764ed9c466294..d185725e100c0 100644
--- a/drivers/md/md.c
+++ b/drivers/md/md.c
@@ -8906,7 +8906,8 @@ void md_reap_sync_thread(struct mddev *mddev)
/* resync has finished, collect result */
md_unregister_thread(&mddev->sync_thread);
if (!test_bit(MD_RECOVERY_INTR, &mddev->recovery) &&
- !test_bit(MD_RECOVERY_REQUESTED, &mddev->recovery)) {
+ !test_bit(MD_RECOVERY_REQUESTED, &mddev->recovery) &&
+ mddev->degraded != mddev->raid_disks) {
/* success...*/
/* activate any spares */
if (mddev->pers->spare_active(mddev)) {
--