[PATCH 5.3 44/95] mdio_bus: Fix init if CONFIG_RESET_CONTROLLER=n
From: Greg Kroah-Hartman
Date: Wed Nov 27 2019 - 16:19:19 EST
From: Geert Uytterhoeven <geert+renesas@xxxxxxxxx>
commit 6e4ff1c94a0477598ddbe4da47530aecdb4f7dff upstream.
Commit 1d4639567d97 ("mdio_bus: Fix PTR_ERR applied after initialization
to constant") accidentally changed a check from -ENOTSUPP to -ENOSYS,
causing failures if reset controller support is not enabled. E.g. on
r7s72100/rskrza1:
sh-eth e8203000.ethernet: MDIO init failed: -524
sh-eth: probe of e8203000.ethernet failed with error -524
Seen on r8a7740/armadillo, r7s72100/rskrza1, and r7s9210/rza2mevb.
Fixes: 1d4639567d97 ("mdio_bus: Fix PTR_ERR applied after initialization to constant")
Signed-off-by: Geert Uytterhoeven <geert+renesas@xxxxxxxxx>
Cc: YueHaibing <yuehaibing@xxxxxxxxxx>
Cc: David S. Miller <davem@xxxxxxxxxxxxx>
Signed-off-by: Linus Torvalds <torvalds@xxxxxxxxxxxxxxxxxxxx>
Signed-off-by: David S. Miller <davem@xxxxxxxxxxxxx>
Cc: Marek BehÃn <marek.behun@xxxxxx>
Signed-off-by: Greg Kroah-Hartman <gregkh@xxxxxxxxxxxxxxxxxxx>
---
drivers/net/phy/mdio_bus.c | 11 ++++++-----
1 file changed, 6 insertions(+), 5 deletions(-)
--- a/drivers/net/phy/mdio_bus.c
+++ b/drivers/net/phy/mdio_bus.c
@@ -68,11 +68,12 @@ static int mdiobus_register_reset(struct
if (mdiodev->dev.of_node)
reset = devm_reset_control_get_exclusive(&mdiodev->dev,
"phy");
- if (PTR_ERR(reset) == -ENOENT ||
- PTR_ERR(reset) == -ENOTSUPP)
- reset = NULL;
- else if (IS_ERR(reset))
- return PTR_ERR(reset);
+ if (IS_ERR(reset)) {
+ if (PTR_ERR(reset) == -ENOENT || PTR_ERR(reset) == -ENOTSUPP)
+ reset = NULL;
+ else
+ return PTR_ERR(reset);
+ }
mdiodev->reset_ctrl = reset;