Re: [PATCH] i2c: meson: implement the master_xfer_atomic callback
From: Wolfram Sang
Date: Mon Jan 13 2020 - 17:15:37 EST
On Wed, Jan 08, 2020 at 12:29:01AM +0100, Martin Blumenstingl wrote:
> Boards with some of the 32-bit SoCs (mostly Meson8 and Meson8m2) use a
> Ricoh RN5T618 PMU which acts as system power controller. The driver for
> the system power controller may need to the I2C bus just before shutting
> down or rebooting the system. At this stage the interrupts may be
> disabled already.
>
> Implement the master_xfer_atomic callback so the driver for the RN5T618
> PMU can communicate properly with the PMU when shutting down or
> rebooting the board. The CTRL register has a status bit which can be
> polled to determine when processing has completed. According to the
> public S805 datasheet the value 0 means "idle" and 1 means "running".
>
> Signed-off-by: Martin Blumenstingl <martin.blumenstingl@xxxxxxxxxxxxxx>
Applied to for-next, thanks!
Attachment:
signature.asc
Description: PGP signature