Re: [PATCH net-next v3 02/11] net: ethernet: ti: cpts: separate hw counter read from timecounter
From: Richard Cochran
Date: Thu Mar 26 2020 - 10:18:09 EST
On Fri, Mar 20, 2020 at 09:42:35PM +0200, Grygorii Strashko wrote:
> Separate hw counter read from timecounter code:
> - add CPTS context field to store current HW counter value
> - move HW timestamp request and FIFO read code out of timecounter code
> - convert cyc2time on event reception in cpts_fifo_read()
> - call timecounter_read() in cpts_fifo_read() to update tk->cycle_last
This comment tells us WHAT the patch does, but does not help because
we can see that from the patch itself. Instead, the comment should
tell us WHY is change is needed.
I was left scratching my head, with the question, what is the purpose
here? Maybe the answer is to be found later on in the series.
Here is commit message pattern to follow that I learned from tglx:
1. context
2. problem
3. solution
For this patch, the sentence, "Separate hw counter read from
timecounter code" is #3.
Thanks,
Richard