[PATCH 08/13] ARM: dts: exynos: Add max77686 clocks for S3C RTC in SMDK5250

From: Krzysztof Kozlowski
Date: Tue Sep 01 2020 - 03:55:06 EST


Add clock-cells to max77686 PMIC node so its 32 kHz clocks could be used
later in the S3C RTC node. Except making the S3C RTC working, this also
fixes dtbs_check warnings:

arch/arm/boot/dts/exynos5250-smdk5250.dt.yaml: rtc@101e0000: clocks: [[2, 337]] is too short
arch/arm/boot/dts/exynos5250-smdk5250.dt.yaml: rtc@101e0000: clock-names: ['rtc'] is too short

Signed-off-by: Krzysztof Kozlowski <krzk@xxxxxxxxxx>
---
arch/arm/boot/dts/exynos5250-smdk5250.dts | 6 +++++-
1 file changed, 5 insertions(+), 1 deletion(-)

diff --git a/arch/arm/boot/dts/exynos5250-smdk5250.dts b/arch/arm/boot/dts/exynos5250-smdk5250.dts
index 5c42df024adf..00af7fb65080 100644
--- a/arch/arm/boot/dts/exynos5250-smdk5250.dts
+++ b/arch/arm/boot/dts/exynos5250-smdk5250.dts
@@ -7,6 +7,7 @@
*/

/dts-v1/;
+#include <dt-bindings/clock/maxim,max77686.h>
#include <dt-bindings/gpio/gpio.h>
#include <dt-bindings/interrupt-controller/irq.h>
#include "exynos5250.dtsi"
@@ -129,13 +130,14 @@
reg = <0x50>;
};

- max77686@9 {
+ max77686: pmic@9 {
compatible = "maxim,max77686";
reg = <0x09>;
interrupt-parent = <&gpx3>;
interrupts = <2 IRQ_TYPE_NONE>;
pinctrl-names = "default";
pinctrl-0 = <&max77686_irq>;
+ #clock-cells = <1>;
wakeup-source;

voltage-regulators {
@@ -368,6 +370,8 @@

&rtc {
status = "okay";
+ clocks = <&clock CLK_RTC>, <&max77686 MAX77686_CLK_AP>;
+ clock-names = "rtc", "rtc_src";
};

&sata {
--
2.17.1