Re: [PATCH v2] dt-bindings: clock: adi,axi-clkgen: convert old binding to yaml format
From: Rob Herring
Date: Fri Oct 16 2020 - 13:22:57 EST
On Tue, 13 Oct 2020 17:34:20 +0300, Alexandru Ardelean wrote:
> This change converts the old binding for the AXI clkgen driver to a yaml
> format.
>
> As maintainers, added:
> - Lars-Peter Clausen <lars@xxxxxxxxxx> - as original author of driver &
> binding
> - Michael Hennerich <michael.hennerich@xxxxxxxxxx> - as supporter of
> Analog Devices drivers
>
> Acked-by: Michael Hennerich <michael.hennerich@xxxxxxxxxx>
> Acked-by: Lars-Peter Clausen <lars@xxxxxxxxxx>
> Signed-off-by: Alexandru Ardelean <alexandru.ardelean@xxxxxxxxxx>
> ---
>
> Changelog v1 -> v2:
> * add 'additionalProperties: false'
> * changed 'clock@...' -> 'clock-controller@...' in example
> * added Acked-by for Michael & Lars on the re-licensing
> * updated description for 'clocks' property
>
> .../bindings/clock/adi,axi-clkgen.yaml | 53 +++++++++++++++++++
> .../devicetree/bindings/clock/axi-clkgen.txt | 25 ---------
> 2 files changed, 53 insertions(+), 25 deletions(-)
> create mode 100644 Documentation/devicetree/bindings/clock/adi,axi-clkgen.yaml
> delete mode 100644 Documentation/devicetree/bindings/clock/axi-clkgen.txt
>
Reviewed-by: Rob Herring <robh@xxxxxxxxxx>