Re: [PATCH] regulator: rt5033: Use linear ranges to map all voltage selection
From: Mark Brown
Date: Mon Jul 05 2021 - 12:53:32 EST
On Fri, Jul 02, 2021 at 11:47:50PM +0800, ChiYuan Huang wrote:
> ChiYuan Huang <u0084500@xxxxxxxxx> 於 2021年7月1日 週四 下午1:53寫道:
> > Axel Lin <axel.lin@xxxxxxxxxx> 於 2021年7月1日 週四 下午12:41寫道:
> > From the regulator register in probe, it will get the current voltage
> > from the IC.
> > If the vout sel is not is over N_VOLTAGES, it will return the error number.
> > But as I think it's the side effect to change the vout step num.
> > To use the linear range is just to guarantee all vout sel range are included.
> > That's my initial thoughts.
> Like as you said, the first revision is from 2014.
> It is almost EOL for this product.
> To fix this seems redundant.
Even if something is old it's still posible that people can use it, and
if someone's done the work to fix it then why not?
Attachment: