[PATCH 1/2] power: supply: max17042_battery: Clear status bits in interrupt handler

From: Sebastian Krzyszkowiak
Date: Sun Sep 12 2021 - 16:54:31 EST


The gauge requires us to clear the status bits manually for some alerts
to be properly dismissed. Previously the IRQ was configured to react only
on falling edge, which wasn't technically correct (the ALRT line is active
low), but it had a happy side-effect of preventing interrupt storms
on uncleared alerts from happening.

Fixes: 7fbf6b731bca ("power: supply: max17042: Do not enforce (incorrect) interrupt trigger type")
Cc: <stable@xxxxxxxxxxxxxxx>
Signed-off-by: Sebastian Krzyszkowiak <sebastian.krzyszkowiak@xxxxxxx>
---
drivers/power/supply/max17042_battery.c | 3 +++
1 file changed, 3 insertions(+)

diff --git a/drivers/power/supply/max17042_battery.c b/drivers/power/supply/max17042_battery.c
index 8dffae76b6a3..c53980c8432a 100644
--- a/drivers/power/supply/max17042_battery.c
+++ b/drivers/power/supply/max17042_battery.c
@@ -876,6 +876,9 @@ static irqreturn_t max17042_thread_handler(int id, void *dev)
max17042_set_soc_threshold(chip, 1);
}

+ regmap_clear_bits(chip->regmap, MAX17042_STATUS,
+ 0xFFFF & ~(STATUS_POR_BIT | STATUS_BST_BIT));
+
power_supply_changed(chip->battery);
return IRQ_HANDLED;
}
--
2.33.0