Re: [PATCH 2/6] clk: samsung: clk-pll: Implement pll0822x PLL type

From: Krzysztof Kozlowski
Date: Wed Sep 15 2021 - 04:24:40 EST


On 14/09/2021 17:56, Sam Protsenko wrote:
> pll0822x PLL is used in Exynos850 SoC for top-level integer PLLs. The
> code was derived from very similar pll35xx type, with next differences:
>
> 1. Lock time for pll0822x is 150*P_DIV, when for pll35xx it's 270*P_DIV
> 2. It's not suggested in Exynos850 TRM that S_DIV change doesn't require
> performing PLL lock procedure (which is done in pll35xx
> implementation)
>
> When defining pll0822x type, CON3 register offset should be provided as
> a "con" parameter of PLL() macro, like this:
>
> PLL(pll_0822x, 0, "fout_shared0_pll", "oscclk",
> PLL_LOCKTIME_PLL_SHARED0, PLL_CON3_PLL_SHARED0,
> exynos850_shared0_pll_rates),
>
> To define PLL rates table, one can use PLL_35XX_RATE() macro, e.g.:
>
> PLL_35XX_RATE(26 * MHZ, 1600 * MHZ, 800, 13, 0)
>
> as it's completely appropriate for pl0822x type and there is no sense in
> duplicating that.
>
> If bit #1 (MANUAL_PLL_CTRL) is not set in CON1 register, it won't be
> possible to set new rate, with next error showing in kernel log:
>
> Could not lock PLL fout_shared1_pll
>
> That can happen for example if bootloader clears that bit beforehand.
> PLL driver doesn't account for that, so if MANUAL_PLL_CTRL bit was
> cleared, it's assumed it was done for a reason and it shouldn't be
> possible to change that PLL's rate at all.
>
> Signed-off-by: Sam Protsenko <semen.protsenko@xxxxxxxxxx>
> ---
> drivers/clk/samsung/clk-pll.c | 91 +++++++++++++++++++++++++++++++++++
> drivers/clk/samsung/clk-pll.h | 1 +
> 2 files changed, 92 insertions(+)
>


Reviewed-by: Krzysztof Kozlowski <krzysztof.kozlowski@xxxxxxxxxxxxx>


Best regards,
Krzysztof