Re: [PATCH 5.10 157/236] Bluetooth: Move shutdown callback before flushing tx and rx queue

From: Guenter Roeck
Date: Wed Sep 15 2021 - 10:32:43 EST


On Wed, Sep 15, 2021 at 01:18:43PM +0200, Pavel Machek wrote:
> Hi!
>
> > [ Upstream commit 0ea53674d07fb6db2dd7a7ec2fdc85a12eb246c2 ]
>
> Upstream commit is okay...
>
> > So move the shutdown callback before flushing TX/RX queue to resolve the
> > issue.
>
> ...but something went wrong in stable. This is not moving code, this
> is duplicating it:
>
> > --- a/net/bluetooth/hci_core.c
> > +++ b/net/bluetooth/hci_core.c
> > @@ -1726,6 +1726,14 @@ int hci_dev_do_close(struct hci_dev *hdev)
> > hci_request_cancel_all(hdev);
> > hci_req_sync_lock(hdev);
> >
> > + if (!hci_dev_test_flag(hdev, HCI_UNREGISTER) &&
> > + !hci_dev_test_flag(hdev, HCI_USER_CHANNEL) &&
> > + test_bit(HCI_UP, &hdev->flags)) {
> > + /* Execute vendor specific shutdown routine */
> > + if (hdev->shutdown)
> > + hdev->shutdown(hdev);
> > + }
> > +
> > if (!test_and_clear_bit(HCI_UP, &hdev->flags)) {
> > cancel_delayed_work_sync(&hdev->cmd_timer);
> > hci_req_sync_unlock(hdev);
>
> And yes, we end up with 2 copies in 5.10.
>

Same problem in v5.4.y, unfortunately.

Guenter

> Best regards,
> Pavel
> --
> DENX Software Engineering GmbH, Managing Director: Wolfgang Denk
> HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany