[PATCH 5.13 069/380] HID: input: do not report stylus battery state as "full"

From: Greg Kroah-Hartman
Date: Thu Sep 16 2021 - 12:39:28 EST


From: Dmitry Torokhov <dmitry.torokhov@xxxxxxxxx>

[ Upstream commit f4abaa9eebde334045ed6ac4e564d050f1df3013 ]

The power supply states of discharging, charging, full, etc, represent
state of charging, not the capacity level of the battery (for which
we have a separate property). Current HID usage tables to not allow
for expressing charging state of the batteries found in generic
styli, so we should simply assume that the battery is discharging
even if current capacity is at 100% when battery strength reporting
is done via HID interface. In fact, we were doing just that before
commit 581c4484769e.

This change helps UIs to not mis-represent fully charged batteries in
styli as being charging/topping-off.

Fixes: 581c4484769e ("HID: input: map digitizer battery usage")
Reported-by: Kenneth Albanowski <kenalba@xxxxxxxxxx>
Signed-off-by: Dmitry Torokhov <dmitry.torokhov@xxxxxxxxx>
Signed-off-by: Jiri Kosina <jkosina@xxxxxxx>
Signed-off-by: Sasha Levin <sashal@xxxxxxxxxx>
---
drivers/hid/hid-input.c | 2 --
1 file changed, 2 deletions(-)

diff --git a/drivers/hid/hid-input.c b/drivers/hid/hid-input.c
index 68c8644234a4..f43b40450e97 100644
--- a/drivers/hid/hid-input.c
+++ b/drivers/hid/hid-input.c
@@ -419,8 +419,6 @@ static int hidinput_get_battery_property(struct power_supply *psy,

if (dev->battery_status == HID_BATTERY_UNKNOWN)
val->intval = POWER_SUPPLY_STATUS_UNKNOWN;
- else if (dev->battery_capacity == 100)
- val->intval = POWER_SUPPLY_STATUS_FULL;
else
val->intval = POWER_SUPPLY_STATUS_DISCHARGING;
break;
--
2.30.2