[PATCH v2 1/4] input: ti_am335x_tsc: set ADCREFM for X configuration

From: Dario Binacchi
Date: Thu Nov 25 2021 - 17:58:01 EST


As reported by the STEPCONFIG[1-16] registered field descriptions of the
TI reference manual, for the ADC "in single ended, SEL_INM_SWC_3_0 must
be 1xxx".

Unlike the Y and Z coordinates, this bit has not been set for the step
configuration registers used to sample the X coordinate.

Fixes: 1b8be32e691 ("Input: add support for TI Touchscreen controller")
Signed-off-by: Dario Binacchi <dariobin@xxxxxxxxx>
---

(no changes since v1)

drivers/input/touchscreen/ti_am335x_tsc.c | 3 ++-
1 file changed, 2 insertions(+), 1 deletion(-)

diff --git a/drivers/input/touchscreen/ti_am335x_tsc.c b/drivers/input/touchscreen/ti_am335x_tsc.c
index 83e685557a19..fd3ffdd23470 100644
--- a/drivers/input/touchscreen/ti_am335x_tsc.c
+++ b/drivers/input/touchscreen/ti_am335x_tsc.c
@@ -131,7 +131,8 @@ static void titsc_step_config(struct titsc *ts_dev)
u32 stepenable;

config = STEPCONFIG_MODE_HWSYNC |
- STEPCONFIG_AVG_16 | ts_dev->bit_xp;
+ STEPCONFIG_AVG_16 | ts_dev->bit_xp |
+ STEPCONFIG_INM_ADCREFM;
switch (ts_dev->wires) {
case 4:
config |= STEPCONFIG_INP(ts_dev->inp_yp) | ts_dev->bit_xn;
--
2.17.1