RE: [PATCH v2 3/4] dt-bindings: watchdog: da9062: add watchdog timeout mode
From: Adam Thomson
Date: Tue Nov 30 2021 - 12:47:31 EST
On 30 November 2021 16:40, Guenter Roeck wrote:
> >> Why does it need a value ? Why not just bool ?
> >
> > One argument might be that if the property isn't provided then the OTP
> > configured value can persist without needing a FW change around this DT
> binding.
> >
> > My belief though is that the majority of users would have this property set to 0
> > by default in OTP, so a boolean would be OK I think here to enable watchdog
> > shutdown.
> >
>
> Sorry, you lost me.
> dlg,wdt-sd = <0>;
> is the current situation, and identical to not having the property in
> the first place.
> dlg,wdt-sd = <1>;
> is new. I don't see the difference to
> dlg,wdt-sd;
> vs. not having the property at all (which is, again, the current situation).
> Since it has to be backward compatible,
> dlg,wdt-sd = <0>;
> will always be identical to not having the property at all.
> I can not find a situation where an integer would have any benefits over a
> boolean.
So if you have a binary DT binding, it's either there or it isn't which implies
the bit to be set to 0/1 in this case. If you have a binding which has a value,
there can be 3 outcomes in this discussion:
1) Binding = 0, bit is set to 0
2) Binding = 1, bit is set to 1
3) Binding NOT present in DT, OTP default value in HW remains untouched
Say a platform updates to a later kernel version, but sticks with existing DT
FW (i.e. the new boolean binding isn't present in FW), then the following could
happen:
1) OTP for DA9061/2 has this bit set to 1, system expectation is that watchdog
triggers SHUTDOWN.
2) New driver checks existance of 'dlg,wdt-sd' but it's obviously not there so
assumes the bit should be set to 0 and does so
3) When the watchdog fires, it will no longer trigger SHUTDOWN but instead
POWER-DOWN due to binary handling of new boolean binding.