Re: [net-next RFC PATCH 03/14] dt-bindings: net: document ethernet PHY package nodes

From: Russell King (Oracle)
Date: Fri Nov 24 2023 - 07:02:41 EST


On Fri, Nov 24, 2023 at 07:49:27PM +0800, Jie Luo wrote:
>
>
> On 11/24/2023 3:33 AM, Christian Marangi wrote:
> > On Thu, Nov 23, 2023 at 03:57:58PM +0100, Andrew Lunn wrote:
> > > On Thu, Nov 23, 2023 at 02:35:31PM +0000, Russell King (Oracle) wrote:
> > > > On Thu, Nov 23, 2023 at 03:27:05PM +0100, Andrew Lunn wrote:
> > > > > > Just to be more precise qca807x can operate in 3 different mode:
> > > > > > (this is controlled by the MODE_CFG bits)
> > > > >
> > > > > > - QSGMII: 5 copper port
> > > > >
> > > > > 4 slots over QSGMII, plus the second SERDES is connected to the MAC
> > > > > using SGMII/1000BaseX?
> > > > >
> > > > > > - PSGMII: 5 copper port
> > > > >
> > > > > 5 slots over QSGMII, the second SERDES is idle?
> > > > >
> > > > > > - PSGMII: 4 copper port + 1 combo (that can be both fiber or copper)
> > > > >
> > > > > 5 slots over QSGMII, with the second SERDES connected to an SFP cage.
> > > > >
> > > > > Are ports 1-4 always connected to the P/Q SGMII. Its only port 5 which
> > > > > can use the second SERDES?
> > > >
> > > > I think what would really help here is if there was an ascii table to
> > > > describe the configurations, rather than trying to put it into words.
> > >
> > > Yes.
> > >
> > > And also for ipq4019. We need to merge these two threads of
> > > conversation, since in the end they are probably the same driver, same
> > > device tree etc.
> > >
> >
> > For everyone that missed Robert response in patch 12 let me quote him
> > also here.
> >
> > "
> > Hi Andrew,
> > I think that the description is confusing.
> > QCA807x supports 3 different modes:
> > 1. PSGMII (5 copper ports)
> > 2. PSGMII (4 copper ports + 1 combo port)
> > 3. QSGMII+SGMII
> >
> > So, in case option 2 is selected then the combo port can also be used for
> > 1000Base-X and 100Base-FX modules or copper and it will autodetect the
> > exact media.
> > This is supported via the SFP op-s and I have been using it without issues
> > for a while.
> >
> > I have not tested option 3 in combination with SFP to the copper
> > module so I cant
> > say whether that works.
>
> For the option3, the last PHY works on SGMII mode, then it can't be
> used with SFP, only copper is supported in this mode.

So, from what you've written, and looking at the PDF for QCA8075:

First Serdes mode Second Serdes mode
Option 1 PSGMII for copper Disabled
ports 0-4
Option 2 PSGMII for copper 1000BASE-X / 100BASE-FX
ports 0-4
Option 3 QSGMII for copper SGMII for
ports 0-3 copper port 4

In all cases, ports 0-4 have a copper (baseT/baseTx/baseTe) port
available.



This is a much easier to understand presentation than writing out a
longwinded description of the three modes. Please include the table
and the statement below the table in the commit description as that
is necessary to describe the hardware setup being addressed in these
patches.

Thanks.

--