Hi Tomi,
On Thu, Sep 5, 2024 at 11:29 AM Tomi Valkeinen
<tomi.valkeinen@xxxxxxxxxxxxxxxx> wrote:
On 05/09/2024 13:27, Lad, Prabhakar wrote:
Hi Tomi,
On Thu, Sep 5, 2024 at 10:11 AM Tomi Valkeinen
<tomi.valkeinen@xxxxxxxxxxxxxxxx> wrote:
<snip>
Yes, based on the previous feedback received, I am implementingI think you actually want 1/0->0/0 routing. The error says that the sink
side device has routing which does not have a stream at stream ID 1, or
no routing support at all, which implies a single stream at stream ID 0.
Looking at patch 12, there's something wrong with the approach here. Are
you perhaps trying to define the CSI-2 VC with the streams?
virtual channels as streams. If this isn't the correct approach can
you please guide me on what we should be using to support virtual
channels?
Can you describe what kind of hardware you have and how the VCs are
supposed to be configured and used there?
__________________ ______________
_____________________
| | |
| |
|
| OV5645 Sensor | | RZ/G2L CSI2 |
| RZ/G2L CRU |
| 1ch out of 4x VC |---------------> | 4x VC
|-------------->| 1Ch capture out 4xVC |
|__________________| |_____________|
|____________________|