On Wed, Sep 11, 2024 at 12:43:27PM +0200, AngeloGioacchino Del Regno wrote:
There is no reason to make specifying the clock-names property
mandatory, as the Global Command Engine HW needs only one clock.
Have you checked to make sure that there are no users that do the lookup
by name?
Signed-off-by: AngeloGioacchino Del Regno <angelogioacchino.delregno@xxxxxxxxxxxxx>
---
.../bindings/mailbox/mediatek,gce-mailbox.yaml | 11 -----------
1 file changed, 11 deletions(-)
diff --git a/Documentation/devicetree/bindings/mailbox/mediatek,gce-mailbox.yaml b/Documentation/devicetree/bindings/mailbox/mediatek,gce-mailbox.yaml
index cef9d7601398..ff5d010fbcf0 100644
--- a/Documentation/devicetree/bindings/mailbox/mediatek,gce-mailbox.yaml
+++ b/Documentation/devicetree/bindings/mailbox/mediatek,gce-mailbox.yaml
@@ -56,17 +56,6 @@ required:
- interrupts
- clocks
-allOf:
- - if:
- not:
- properties:
- compatible:
- contains:
- const: mediatek,mt8195-gce
- then:
- required:
- - clock-names
-
additionalProperties: false
examples:
--
2.46.0