Re: [PATCH] scsi: pm80xx: Use module param to set pcs event log severity

From: Martin K. Petersen
Date: Fri Oct 25 2024 - 14:46:16 EST



Salomon,

> 3 works well for Google, but a different value might be better for
> others. Having a module parameter would allow users to customize the
> level of logging based on their specific needs. If that is not a
> concern, I can change the default to just 3.

How verbose will a value of 3 be during normal operation? I don't object
to capturing more information during failure scenarios as long as we're
not flooding the logs with noise when things are nominal.

--
Martin K. Petersen Oracle Linux Engineering