Re: [PATCH v4 1/2] dt-bindings: hwmon: ti,ina2xx: Add INA233 device
From: Krzysztof Kozlowski
Date: Fri Jan 17 2025 - 03:31:28 EST
On Thu, Jan 16, 2025 at 09:52:08PM +0800, Leo Yang wrote:
> Hi Krzysztof,
>
> On Thu, Jan 16, 2025 at 6:47 PM Krzysztof Kozlowski <krzk@xxxxxxxxxx> wrote:
> >
> > > + This value will be used to calculate the Current_LSB and current/power
> > > + coefficient for the pmbus and to calibrate the IC.
> > > + minimum: 32768
> > > + maximum: 4294967295
> >
> > Uh, are these real values measurable by the device? The last one looks
> > like UINT_MAX.
>
> According to the spec I don't see a definition of the upper limit of the
> current measurement, it all depends on how low the shunt resistance can
> be, so I'll use the upper limit of the u32 as the maximum for now, even
> though it's unlikely that this number will be present in the actual circuit.
>
> >
> > > + default: 32768000
> >
> > Default is 32 A? For what applications is this sensor used?
> >
>
> According to spec 8.2.2.1 Programming the Calibration Register example,
> a Current_LSB with a maximum expected current of 15A is approximately
> 457.7uA.
> The example shows that a Current_LSB of 500 or 1000uA/bit can be used.
> So I choose 1000uA as the default value here, this value corresponds to
> the expected maximum current which is 32A (with some loss of accuracy to
> have a larger measurement range), and yes maybe the user doesn't
> need such a large current, so the accuracy-sensitive use of the scene
> can be adjusted according to the actual measurement range of the
> expected maximum current, I'm trying to retain some flexibility for the
> user.
>
Datasheet indeed does not describe actual limits, expect 5 mA on the
pin, but that depends on shunt resistor, so fine with me:
Reviewed-by: Krzysztof Kozlowski <krzysztof.kozlowski@xxxxxxxxxx>
Best regards,
Krzysztof