Hi Angelo,
Am 14. April 2025 12:25:23 MESZ schrieb AngeloGioacchino Del Regno <angelogioacchino.delregno@xxxxxxxxxxxxx>:
Il 13/04/25 10:58, Frank Wunderlich ha scritto:
From: Frank Wunderlich <frank-w@xxxxxxxxxxxxxxx>
Topmisc is a systemcontroller used for xs-phy and ethernet on mt7988.
Add binding for it.
That's the wrong binding... check mfd/syscon.yaml :-)
P.S.: Is there any reset controller in topmisc? Any clock?
If yes, syscon.yaml is also wrong, and you need a driver for that.
Remember: If it turns out *later* that this has clk/resets and the
bindings are already set for just a syscon, it's gonna be way harder!
Cheers,
Angelo
Ok based on the power-domain-cells property i guessed powercontroller is the right place.
But based on your suggestion i tried moving compatible to syscon binding and made dtbs_check here.
I can confirm dropping the unexpected properties reported by syscon binding (power-domain-cells,clock-cells,adress-cells and size-cells) are not needed for function (xsphy and ethernet).
For verifying that there are really no clocks/resets in topmisc (have not found it in public available register documents) i asked mtk (waiting for answer).
Also got it working without the syscon compatible by changing ethernet driver too (after this change xsphy was also working).
Eth:
https://github.com/frank-w/BPI-Router-Linux/commit/d866e648717800b6f6395ad36c38f9effcf0498d
Xsphy:
<https://github.com/frank-w/BPI-Router-Linux/commit/0121a94df99700487704ca056b210b13db07e90c>
regards Frank