[PATCH v4 2/4] dt-bindings: iio: flow: add Sensirion SLF3S liquid flow sensor
From: Wadim Mueller
Date: Thu Jun 11 2026 - 09:27:31 EST
Document the bindings for the Sensirion SLF3S family of digital
liquid-flow sensors on I2C. The family currently covers the
SLF3S-0600F, SLF3S-1300F and SLF3S-4000B variants.
All variants share the same register map and are fully detectable
from the product-information register at probe time, so
sensirion,slf3s-1300f serves as the fallback compatible for the
other variants.
The active calibration medium (water / IPA) is runtime-switchable
via the in_volumeflow_medium sysfs attribute and therefore not a
DT property.
Signed-off-by: Wadim Mueller <wafgo01@xxxxxxxxx>
---
.../bindings/iio/flow/sensirion,slf3s.yaml | 58 +++++++++++++++++++
MAINTAINERS | 7 +++
2 files changed, 65 insertions(+)
create mode 100644 Documentation/devicetree/bindings/iio/flow/sensirion,slf3s.yaml
diff --git a/Documentation/devicetree/bindings/iio/flow/sensirion,slf3s.yaml b/Documentation/devicetree/bindings/iio/flow/sensirion,slf3s.yaml
new file mode 100644
index 000000000..c054a505b
--- /dev/null
+++ b/Documentation/devicetree/bindings/iio/flow/sensirion,slf3s.yaml
@@ -0,0 +1,58 @@
+# SPDX-License-Identifier: (GPL-2.0-only OR BSD-2-Clause)
+%YAML 1.2
+---
+$id: http://devicetree.org/schemas/iio/flow/sensirion,slf3s.yaml#
+$schema: http://devicetree.org/meta-schemas/core.yaml#
+
+title: Sensirion SLF3S liquid flow sensor
+
+maintainers:
+ - Wadim Mueller <wafgo01@xxxxxxxxx>
+
+description:
+ Family of digital liquid-flow sensors from Sensirion with I2C interface. All
+ family members share the same register map; sub-types differ only in the flow
+ scale factor and the calibrated measurement range. The sub-type can be
+ identified from the product-information register.
+
+properties:
+ compatible:
+ oneOf:
+ - const: sensirion,slf3s-1300f
+ - items:
+ - enum:
+ - sensirion,slf3s-0600f
+ - sensirion,slf3s-4000b
+ - const: sensirion,slf3s-1300f
+
+ reg:
+ maxItems: 1
+
+ vdd-supply: true
+
+ interrupts:
+ maxItems: 1
+
+required:
+ - compatible
+ - reg
+ - vdd-supply
+
+additionalProperties: false
+
+examples:
+ - |
+ #include <dt-bindings/interrupt-controller/irq.h>
+
+ i2c {
+ #address-cells = <1>;
+ #size-cells = <0>;
+
+ flow-sensor@8 {
+ compatible = "sensirion,slf3s-0600f", "sensirion,slf3s-1300f";
+ reg = <0x08>;
+ vdd-supply = <®_3v3>;
+ interrupt-parent = <&gpio0>;
+ interrupts = <0 IRQ_TYPE_EDGE_RISING>;
+ };
+ };
diff --git a/MAINTAINERS b/MAINTAINERS
index 06a8c7457..cdc18a601 100644
--- a/MAINTAINERS
+++ b/MAINTAINERS
@@ -24187,6 +24187,13 @@ S: Maintained
F: Documentation/ABI/testing/sysfs-bus-iio-chemical-sgp40
F: drivers/iio/chemical/sgp40.c
+SENSIRION SLF3S LIQUID FLOW SENSOR DRIVER
+M: Wadim Mueller <wafgo01@xxxxxxxxx>
+R: Maxwell Doose <m32285159@xxxxxxxxx>
+L: linux-iio@xxxxxxxxxxxxxxx
+S: Maintained
+F: Documentation/devicetree/bindings/iio/flow/sensirion,slf3s.yaml
+
SENSIRION SPS30 AIR POLLUTION SENSOR DRIVER
M: Tomasz Duszynski <tduszyns@xxxxxxxxx>
S: Maintained
--
2.52.0