Re: [PATCH v4 2/4] dt-bindings: iio: flow: add Sensirion SLF3S liquid flow sensor
From: Krzysztof Kozlowski
Date: Thu Jun 11 2026 - 10:02:45 EST
On 11/06/2026 15:26, Wadim Mueller wrote:
> Document the bindings for the Sensirion SLF3S family of digital
> liquid-flow sensors on I2C. The family currently covers the
> SLF3S-0600F, SLF3S-1300F and SLF3S-4000B variants.
>
> All variants share the same register map and are fully detectable
> from the product-information register at probe time, so
> sensirion,slf3s-1300f serves as the fallback compatible for the
> other variants.
>
> The active calibration medium (water / IPA) is runtime-switchable
> via the in_volumeflow_medium sysfs attribute and therefore not a
> DT property.
>
> Signed-off-by: Wadim Mueller <wafgo01@xxxxxxxxx>
> ---
Reviewed-by: Krzysztof Kozlowski <krzysztof.kozlowski@xxxxxxxxxxxxxxxx>