Re: [PATCH v2] iio: light: apds9306: fix default sampling frequency definition

From: Andy Shevchenko

Date: Thu Sep 03 2026 - 04:07:48 EST


On Thu, Sep 03, 2026 at 05:05:35PM +1000, Tsz Shan Chan wrote:
> APDS9306_SAMP_FREQ_10HZ is defined as 0.
>
> According to the datasheet (Broadcom AV02-4755EN,
> https://docs.broadcom.com/doc/AV02-4755EN, page 11, ALS_MEAS_RATE),

Make it a tag

> bits[2:0] set the measurement rate:
> - 000: 25ms (40Hz)
> - 001: 20ms (20Hz)
> - 010: 100ms (10Hz)
>
> Change APDS9306_SAMP_FREQ_10HZ from 0 to 2 to write the correct value
> for 10Hz.

Datasheet: $URL

> Fixes: 620d1e6c7a3f ("iio: light: Add support for APDS9306 Light Sensor")
> Signed-off-by: Tsz Shan Chan <tchan@xxxxxxxxxxxxxx>

With that being addressed,
Reviewed-by: Andy Shevchenko <andriy.shevchenko@xxxxxxxxx>

--
With Best Regards,
Andy Shevchenko