Re: [PATCH 3/3] arm64: dts: qcom: glymur: Add EC thermal zones
From: Konrad Dybcio
Date: Mon Nov 02 2026 - 06:13:29 EST
On 11/2/26 12:06 PM, Manaf Meethalavalappu Pallikunhi wrote:
> Hi Konrad,
>
> On 10/29/2026 2:38 PM, Anvesh Jain P wrote:
[...]
>>>> +&thermal_zones {
>>>> + ec-back-cover {
>>>> + polling-delay = <10000>;
>>>> + thermal-sensors = <&ec 2>;
>>>> +
>>>> + trips {
>>>> + trip-point0 {
>>>> + temperature = <90000>;
>>> This is *really* hot!
>>>
>>
>> The 90°C trip value was suggested by thermal team(Manaf Meethalavalappu
>> Pallikunhi <manaf.pallikunhi@xxxxxxxxxxxxxxxx>). We are open to using a
>> lower value if this is too high for the keyboard and back-cover sensors.
>
> These sensors are intended to be controlled primarily from userspace by the thermal governor in thermald, through the powercap sysfs interface [1]. We do not plan to add cooling bindings for these thermal zones.
>
> Based on discussions with the tuning team, we agreed on a hot-trip threshold of 90°C for these sensors.
>
> [1] https://github.com/intel/thermal_daemon/pull/614/commits/7f3dd62353e039957e52eeb40c67ec388d543ebe
If you never reach the userspace (e.g. because you're stuck in
initfs) or if the distro doesn't ship thermald, you risk physically
harming the user by explicitly allowing the (metal) back cover to
go to 90C.
Konrad