Re: [PATCH net-next 05/30] net: dsa: mt7530: read XTAL value from correct register
From: Andrew Lunn
Date: Tue May 23 2023 - 20:07:40 EST
On Mon, May 22, 2023 at 03:15:07PM +0300, arinc9.unal@xxxxxxxxx wrote:
> From: Arınç ÜNAL <arinc.unal@xxxxxxxxxx>
>
> On commit 7ef6f6f8d237 ("net: dsa: mt7530: Add MT7621 TRGMII mode support")
> macros for reading the crystal frequency were added under the MT7530_HWTRAP
> register. However, the value given to the xtal variable on
> mt7530_pad_clk_setup() is read from the MT7530_MHWTRAP register instead.
>
> Although the document MT7621 Giga Switch Programming Guide v0.3 states that
> the value can be read from both registers, use the register where the
> macros were defined under.
>
> Tested-by: Arınç ÜNAL <arinc.unal@xxxxxxxxxx>
> Signed-off-by: Arınç ÜNAL <arinc.unal@xxxxxxxxxx>
Reviewed-by: Andrew Lunn <andrew@xxxxxxx>
Andrew