Re: [PATCH] iio: humidity: hdc3020: add threshold events support

From: Javier Carrasco
Date: Sat Feb 03 2024 - 10:53:50 EST


On 03.02.24 15:42, Dimitri Fedrau wrote:
> Am Sat, Feb 03, 2024 at 10:30:09AM +0100 schrieb Javier Carrasco:
>> Hi Dimitri,
>>
> Hi Javier,
>
>>> + /* Supported temperature range is from –40 to 125 degree celsius */
>> Should that not be val < -40?
> yes, you are right. Will fix it.
>>> + if (val < -45 || val > 125)
>>> + return -EINVAL;
>>> +
>
> Best regards,
> Dimitri

When at it, could you please rename the hdc3020_id variable you added to
the probe function? It shadows the i2c_device_id global variable (it is
not used in the probe function, but there is no need to use the exact
same name), and given that it is in the hdc3020_probe function,
mentioning the device name again is kind of redundant. Something like
just "id" or "dev_id" would suffice.

Best regards,
Javier Carrasco